Contact Info
TEL: 028-84193018
FAX: 028-84193058
Add: 515,Building 1,NO39,Jiancai road,Chenghua district,Chengdu,Sichuan,China

YSD18C Portable Large Screen Medical Products Veterinary Monitor

$0.00
INQUIRY
Description

Product  Features
12.1" color TFT touch screen
Windows style, Multi-channel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review
Patient info. Input
Anti-defibrillation design
NIBP over pressure protection
Plug-in rechargeable battery, AC/DC available.
Supporting wire or wireless network.

Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.
Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.

SP02

Nellcor(TM)  OxiMax(TM) is the world leading SpO2 technology
Nellcor(TM)  OxiMax(TM) delivers excellent performance,
even in the difficult monitoring conditions of low perfusion and signal interference, including patient motion.

ETCO2

Collaborate with Respironics, Plug and Play EtCO2 monitoring.
CAPNOSTAT mainstream sensor for optimal performance in monitoring intubated patient. Small, durable and lightweight mainstream sensor provides accurate
and reliable monitoring for all intubated patients from neonates to adults. Loflo sidestream sensor for monitoting non-intubated patient.
Flexible, compact CO2 sensor provides consistent and reliable monitoring of adult, pediatric and neonatal patients.

Multi Mounting Solutions

ECG

Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection                     I, II, III, avR, avL, avF, V
Wave form                          2 ch
Lead mode                          3 Leads ( R, L, F or RA, LA, LL)
Lead selection                     I, II, III,
Wavef orm                          1 ch
Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

HR and Alarm Range                 Adult    15 ~ 300 bpm
                                  Neo/Ped    15 ~ 350 bpm
Accuracy                           ±1% or±1bpm, which is greater
Resolution                         1 bpm
Sensitivity                        > 200 (uVp-p)
Differential Input Impedance       > 5 MΩ

CMRR                    Monitor > 105 dB
                                  Operation > 105 dB
                                  Diagnosis > 85 dB
Electrode offset potential         ±300mV
Leakage Current                    < 10 uA
Baseline Recovery                  < 3 S After Defi.
ECG Signal Range                   ±8 m V ( Vp-p )

Bandwidth                           Surgery    1 ~ 20 Hz
                                   Monitor     0.5 ~ 40 Hz
                                   Diagnostic  0.05 ~ 130 Hz
Calibration Signal                  1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
                                         PNP, PNC,Alarm Available,Review Available

Respiration

Method                            Impedance between R-F(RA-LL)
Differential Input Impedance       > 2.5 MΩ
Measuring Impedance Range          0.3~3 Ω
Base line Impedance Range          200~4 KΩ
Bandwidth                          0.1~2.5Hz
Resp. Rate                         Measuring and Alarm Range
                                   Adult 0 ~ 120 Brpm
                                   Neo/Ped 0 ~ 150 Brpm
                                   Resolution 1 Brpm
                                   Accuracy ±2 Brpm

Apnea Alarm                        10 ~ 40 S

NIBP

Method                            Oscillometric
Mode                              Manual, Auto, STAT                    
Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode     5 Min
Pulse Rate Range           40 ~ 240 bpm
Alarm Type                  SYS, DIA, MEAN

Measuring and alarm range        Adult Mode
                                   SYS 40 ~ 270 mmHg
                                   DIA 10 ~ 215 mmHg
                                   MEAN 20 ~ 235 mmHg
                               Pediatric Mode
                                   SYS 40 ~ 200 mmHg
                                   DIA 10 ~ 150 mmHg
                                   MEAN 20 ~ 165 mmHg
                               Neonatal Mode
                                   SYS 40 ~ 135 mmHg
                                   DIA 10 ~ 100 mmHg
                                   MEAN 20 ~ 110 mmHg
Resolution                      1mmHg

Accuracy                        Maximum Mean error ±5mmHg
                               Maximum Standard deviation ±8mmHg
Overpressure Protection          Adult Mode 297±3 mmHg
                                Pediatric Mode 240±3 mmHg
                                Neonatal Mode 147±3 mmHg

SpO2
Measuring Range                  0 ~ 100 %
Alarm Range                      0 ~ 100 %
Resolution                       1 %
Accuracy                         70% ~ 100%  2 %
                                0%  ~  69% unspecified
Actualization intervalabout      1 Sec.
Alarm Delay                      10 Sec.
Pulse Rate                       Measuring and Alarm Range 20~300 bpm
                                Resolution       1bpm
                                Accuracy ±3bpm
 TEMP

Channe                          2
Measuring and Alarm Range 0 ~ 50 ºC
Resolution                      0.1 ºC
Accuracy                 ±0.2 ºC
Actualization intervalabout     1 Sec.
Average Time Constant           < 10 Sec.

IBP

Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range       ART 0 ~ 300 mmHg
                               PA -6 ~ 120 mmHg
                               CVP/RAP/LAP/ICP-10 ~ 40 mmHg
                               P1 / P2-10 ~ 300 mmHg


Press Sensor                    Sensitivity 5  uV/V/mmHg
                               Impedance 300-3000Ω

Resolution                      1 mmHg
Accuracy                        ±2% or 1mmHg which is greater
Actualization interval         about 1 secretary

Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
Our Certificates:


Why choose us:
we got production and business certification from Chengdu food and Drug Administration
we got business license from Chengdu City Administration of industry and commerce
we got products certificate of registration and have checked in the website of SFDA
we have accepted the onsite check from SFDA every quarter
we finished the training of laws and regulations in medical device field
We have well-established system about material purchasing, employee training,store management,after-sales service process.etc
We adheres the beliefs of "Support Healthy Life", and our company spirits are quality, service,trust,thanksgiving

TOP