Contact Info
TEL: 028-84193018
FAX: 028-84193058
Add: 515,Building 1,NO39,Jiancai road,Chenghua district,Chengdu,Sichuan,China

Multi-parameter patient monitor YSD13D

Item No.: YSD047
Multi-parameter patient monitor
$0.00
INQUIRY
Description

YSD13D multi-parameter patient monitor is a robust patient monitor, small enough to move around, yet flexible enough to adapt to your particular needs. With a variety of optional extras, including arrhythmia and ST analysis, EtCO2 measurement and double IBP, YSD13D multi-parameter patient monitor is configurable to suit your requirements. Purchase only the advanced features that you need and nothing more. With NIBP recall and extensive data storage capability , YSD13D multi-parameter patient monitor is particularly well-suited for use in peri-anesthesia and critical care environments. Rich in functions, conveniently adaptable and pleasingly affordable, YSD13D multi-parameter patient monitor may be just the monitor for your department.


Main Features :
·6 Standard parameters: ECG, RESP, NIBP, SPO2, 2-TEMP, PR/HR.
·12.1"high resolution color TFT LCD display.
·Real time S-T segment analysis, pace-maker detection.
·Indication of Incorrect manipulation and malfunction

    analysis.
·Patient info input management function
·Multi-lead ECG waveforms display in phase.
·Large volume of tabular and graphic trends information

   storage and easy to recall.
·Capture dynamic waveforms.
·Efficient resistance to interference of defibrillator and

    HF knife.
·UP to 2 hours working capacity of built-in rechargeable

   battery.
·Unique accessory management cabinet.
·Networking capacity.
· Option: IBP, ETCO2 and 2-IBP.


Technique parameter:

•NIBP   

 Method:Oscillometry

 Modes:Manual/Auto/Continuous  

 Auto measure time:Adjustable

 Measurement range:10-270mmHg 

•ECG     

Lead mode: 3-lead or 5-lead

Lead selection: I;II;III,avR;avF;avL 

Heart rate range: Adult:15-300bpm; Pediatric/Neonatal:15-300bpm  

ECG waveform: 2 channals  

Accuracy: ±1 bpm or ±1%,which is greater  

S-Tsegment detection;measurement range: -2.0mv~+2.0mv  

Alarm:Yes,audible and  visual alarm,alarm events review 

•SPO2   

Measurement range:0-100%  

Accuracy:70-100%,±2%,0-69%,upspecified  

Auto measure time:Adjustable 

•Pulse Rate  

 Range:20-254bpm  

 Accuracy: ±3bpm  

•Respiration 

 Method:RA-LL impedance   

 Range:Adult:0-120rpm;pediatric/neonatal:0-150rpm  

 Apnca alarm:Yes

•Temperature: 

Range:0-500 

Accuracy: ± 0.10  
Channal:Dual-channel


TOP