12.1′′ Multi-Parameter Patient Monitor ECG, NIBP, SpO2, Temp, Resp Optional Printer Hospital ICU Ccu-Maggie Ysd16L CE Approved

$0.00
INQUIRY
Description

12.1'' Multi-Parameter Patient Monitor ECG, NIBP, SpO2, Temp, Resp Optional Printer Hospital ICU Ccu-Maggie Ysd16L CE Approved
Main Features 

·6 Standard parameters: ECG, RESP, NIBP, SPO2, 2-TEMP, PR/HR.
·12.1"high resolution color TFT LCD display.
·Real time S-T segment analysis, pace-maker detection.
·Indication of Incorrect manipulation and malfunction

 analysis.

·Multichannel display 
·Big font interface
·ST and arrhythmia analysis
·Drug dose calculation and titration table
·OxyCRG dynamic view display
·Respiration monitoring with apnea alarms
·Alarm review, arrhythmia review 
·Patient info. Input 
·Antidefibrillation design
·NIBP over pressure protection
·Plugin rechargeable battery, AC/DC available. 
·Supporting wire or wireless network.
·Patient info input management function

·Multi-lead ECG waveforms display in phase.
·Large volume of tabular and graphic trends information

 storage and easy to recall.
·Capture dynamic waveforms.
·Efficient resistance to interference of defibrillator and

 HF knife.
·UP to 2 hours working capacity of built-in rechargeable

 battery.
·Unique accessory management cabinet.
· Option: IBP, ETCO2 and 2-IBP.


12.1'' Multi-Parameter Patient Monitor ECG, NIBP, SpO2, Temp, Resp Optional Printer Hospital ICU Ccu-Maggie Ysd16L CE Approved

 
Technical Specifications
 
ECG
 
Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 
Lead selection                     I, II, III, avR, avL, avF, V
Wavef orm                           2 ch
Lead mode                          3 Leads ( R, L, F or RA, LA, LL) 
Lead selection                     I, II, III,
Wave form                          1 ch
Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
 
HR and Alarm Range                 Adult    15 ~ 300 bpm
                                   Neo/Ped    15 ~ 350 bpm
Accuracy                           ±1% or±1bpm, which is greater
Resolution                         1 bpm 
Sensitivity                        > 200 (uVp-p) 
Differential Input Impedance       > 5 MΩ
 
CMRR                    Monitor > 105 dB 
                                   Operation > 105 dB 
                                   Diagnosis > 85 dB
Electrode offset potential         ±300mV 
Leakage Current                    < 10 uA
Baseline Recovery                  < 3 S After Defi. 
ECG Signal Range                   ±8 m V ( Vp-p ) 
 
Bandwidth                           Surgery    1 ~ 20 Hz
                                              Monitor     0.5 ~ 40 Hz
                                              Diagnostic  0.05 ~ 130 Hz
Calibration Signal                  1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV
 
ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
                                          PNP, PNC,Alarm Available,Review Available
 
Respiration
 
Method                            Impedance between R-F(RA-LL)
Differential Input Impedance       > 2.5 MΩ
Measuring Impedance Range          0.3~3 Ω
Base line Impedance Range           200~4 KΩ
Bandwidth                          0.1~2.5Hz
Resp. Rate                         Measuring and Alarm Range
                                    Adult 0 ~ 120 Brpm 
                                    Neo/Ped 0 ~ 150 Brpm 
                                    Resolution 1 Brpm 
                                    Accuracy ±2 Brpm
 
Apnea Alarm                        10 ~ 40 S
 
NIBP 
 
Method                            Oscillometric
Mode                              Manual, Auto, STAT                        
Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode     5 Min
Pulse Rate Range           40 ~ 240 bpm
Alarm Type                  SYS, DIA, MEAN
 
Measuring and alarm range        Adult Mode
                                    SYS 40 ~ 270 mmHg 
                                    DIA 10 ~ 215 mmHg 
                                    MEAN 20 ~ 235 mmHg
                                Pediatric Mode
                                    SYS 40 ~ 200 mmHg 
                                    DIA 10 ~ 150 mmHg 
                                    MEAN 20 ~ 165 mmHg
                                Neonatal Mode
                                    SYS 40 ~ 135 mmHg 
                                    DIA 10 ~ 100 mmHg 
                                    MEAN 20 ~ 110 mmHg
Resolution                      1mmHg
 
Accuracy                        Maximum Mean error ±5mmHg
                                Maximum Standard deviation ±8mmHg
Overpressure Protection          Adult Mode 297±3 mmHg 
                                 Pediatric Mode 240±3 mmHg 
                                 Neonatal Mode 147±3 mmHg
 
SpO2
Measuring Range                  0 ~ 100 % 
Alarm Range                      0 ~ 100 % 
Resolution                       1 %
Accuracy                         70% ~ 100%  2 %
                                 0%  ~  69% unspecified
Actualization intervalabout      1 Sec. 
Alarm Delay                      10 Sec.
Pulse Rate                       Measuring and Alarm Range 20~300 bpm
                                 Resolution       1bpm
                                 Accuracy ±3bpm
                                   
TEMP
 
Channel                          2
Measuring and Alarm Range 0 ~ 50 ºC
Resolution                      0.1 ºC
Accuracy                 ±0.1 ºC
Actualization intervalabout     1 Sec.
Average Time Constant           < 10 Sec.
 
IBP
 
Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range       ART 0 ~ 300 mmHg 
                                PA -6 ~ 120 mmHg
                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg
                                P1 / P2-10 ~ 300 mmHg 
 
 
Press Sensor                    Sensitivity 5  uV/V/mmHg
                                Impedance 300-3000Ω
 
Resolution                      1 mmHg
Accuracy                        ±2% or 1mmHg which is greater
Actualization interval         about 1 secretary
 
 
Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
 

Standard configuration
SPO2,PR,NIBP,ECG,RESP,TEMP

Optional configuration
ETCO2 
Nellcor SpO2, IBP, Thermal Recorder

Parameters:

NIBP  Method:Oscillometry
Modes:Manual/Auto/Comtinuous  
Auto measure time:Adjustable
Measurement range:10-300mmHg  
 
ECG  
 
 
 
 
Lead mode: 3-lead or 5-lead
Lead selection: I;II;III,avR;avF;V  
Heart rate range: Adult:15-300bpm;
Pediatric/Neonatal:15-300bpm  
ECG waveform: 2 channals  
Accuracy: ±1 bpm or ±1%,which is greater  
S-T segment detection;measurement range: -2.0mv~+2.0mv  
Alarm:Yes,audible and  visual alarm,alarm events review 
 SPO2Measurement range:0-100%  
Accuracy:70-100%,±2%,0-69%,upspecified  
Auto measure time:Adjustable  
 
Pulse Rate  
Range:20-254bpm  
Accuracy: ±3bpm  
 
Respiration  
Method:RA-LL impedance  
Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm  
 Apnca alarm:Yes
Temperature  Range:0-500
Accuracy: ± 0.10  
Channal:Dual-channel
 Main unitECG cable
Spo2 probe
TEM Probe
NIBP Tube
Adult cuff
Power cable
Battery
User manual


12.1'' Multi-Parameter Patient Monitor ECG, NIBP, SpO2, Temp, Resp Optional Printer Hospital ICU Ccu-Maggie Ysd16L CE Approved