Usage:
Orthopedics: restore bone translocation, reset, fixing
Surgery: taking foreign bodies out of the body, cardiac catheterization, implantable pacemakers, interventional treatment, some of angiography and local photography etc.
Features:
1. With unique base electric auxiliary support arm design, so it’s safer.
2. A unique hand-held controller design, which can control parameter set, device movement and radiation field, so the operation is more convenient
3. With high-quality Combination high frequency high-voltage X-ray generator, it can greatly reduce the amount of X-ray irradiation.
4. With a perspective KV, MA automatic tracking feature, so that the image brightness, sharpness automatically in the best condition
5. Adopting imported image intensifier, the quality is stable and reliable, and the image is of good clarity.
6. With medical progressive output high-resolution television system, it can store 8 images, the image is clearer, and easier to use,
Basic configurations:
1. C-arm mainframe one set
2. Combined high-frequency high-voltage X-ray generator and high-frequency power supply (5.0kW, 40 kHz, 120kV) one set
3. imported 9 inch image intensifier one set
4. Imported medical ultra-low illumination CCD radiography one
5. Digital acquisition and processing station (see workstation list for detail information) one set
6. Imported dense grain grids one set
7. Electrical adjustable beam limiting device one
8. High-definition progressive output CCU control system one set
9.14-inch high-definition medical dedicated monitor one
10. Unique hand-held controller one set
Performance and Parameter:
Category | Items | Content |
Electrical performance | High frequency inverter power supply | Power:5.0kW Main inverter frequency: 40 kHz |
Perspective max rated capacity | Tube current 8 mA Tube voltage 120 kv | |
Automatic fluoroscopy | tube voltage 40 kv~120kv,adjust automatically tube current : 0.3mA~~4mA adjust automatically | |
Manual fluoroscopy | tube voltage 40 kv~120kv, continuous tube current : 0.3mA~~4mA continuous | |
Pulse fluoroscopy | tube voltage 40 kv~120kv, continuous tube current : 4.1mA~~8mA continuous | |
Photography tube voltage, mA | 40KV~120KV, 20mA~100mA | |
Plate holder size | 200mmx250mm(8”x10”) or 250mmx300mm(10”x12”) | |
X-ray tube | X-ray tube special for high frequency | Fluoroscopy focus:0.3 thermal capacity: 500kJ (666kHu) |
Imaging system | Image intensifier | Imported 9 inch image intensifier |
CCD photography | Imported medical ultra-low illumination CCD radiography | |
Monitor | Center definition is 1000 lines and frequency for picture refresh is 75Hz. | |
CCU (central control) | HD progressive output, continuous adjustable recursion, many images storage, upright image, horizontal image, positive & negative image, image patching, LIH(last image freeze), OSD (monitor display). | |
Structure and performance | Direction wheel and main wheel | Direction wheel can rotate in any direction, and main wheel can rotate in ±90°. |
C-arm | The up and down electrical stroke of pillar is 400mm. Forward and backward movement:200mm; Revolution around horizontal axis : ±180°; Revolution around vertical axis: ±15°, distance from focus to screen: 960 mm; C-arm open distance: 760mm C-arm arc depth: 640mm; Slipping on orbit : 120°(+90°~-30°) |